Getting a CNC onto the network, control by control.

The planning that comes first, where each control family keeps its network settings, verification in the right order, and the five faults that cause most delays.

Getting a CNC onto the plant network is the step that delays more monitoring projects than any other, and almost never for a difficult reason. It is usually a duplicate address, a subnet mismatch, a machine on the wrong switch, or an address that changed because nobody reserved it.

This is the consolidated procedure for FANUC, Siemens, Mitsubishi, Haas and Mazak — the planning that comes first, where each control family keeps its network settings, and the verification that stops a commissioning visit being wasted.

Plan before you touch a control

Four decisions that prevent most of the problems.

DECIDE 01A range for machines onlyReserve a block on the plant network used by nothing else. A machine sharing a range with laptops and printers will eventually collide.
DECIDE 02Static, or reservedEither a static address or a DHCP reservation tied to the machine. An ordinary DHCP lease will change, and monitoring will silently lose the machine.
DECIDE 03One subnet mask, written downMismatched masks are the second most common fault and the least obvious — the machine appears configured and is unreachable.
DECIDE 04SegmentationMachines on a segment with no route from general office IT. Settle this with IT before addresses are assigned, not after.

Half an hour spent on these four decisions saves more commissioning time than anything else in this article. Write the result into a sheet — machine number, address, subnet mask, gateway, switch port, date — and keep it with the machine records.

Where the settings live, by control family

Verify against your machine's own manual: labels vary with version.

ControlWhere to goWhat you setNotes
FANUC (0i / 30i families)SYSTEM key, then the Ethernet or Embedded Ethernet screens via the soft keysIP address, subnet mask, router/gatewayThe embedded port and an optional Ethernet board are configured separately — confirm which one is cabled. A power cycle is generally needed.
Siemens SINUMERIK (840D sl / 828D)HMI → Setup / start-up area → network or TCP/IP configurationAddress, subnet mask, gateway for the plant-network interfaceThese controls distinguish interfaces: a system-network port for internal drive traffic, a service port, and a company/plant-network port. Configure the plant-network one — X130 on many NCU and PPU variants.
Mitsubishi (M70 / M80 / M700 / M800)Maintenance or parameter screens, Ethernet parameter areaIP address, subnet mask, gatewayCommonly held in the #1926 / #1927 / #1928 parameter group on M700 and M800 series. Confirm against your manual; a power cycle is required.
Haas (NGC)Settings tab → Network pageWired DHCP off, then IP address, subnet mask, gateway, DNSConnection status is reported on the same page, which makes verification immediate.
Haas (Classic)Numbered settings, 900 seriesDHCP off, then address, mask, gateway, DNSA control power cycle is usually required before the change takes effect.
Mazak (Matrix / Smooth)The control runs on a Windows platform; network configuration is through the Windows network settings on the controlAdapter address, mask, gatewayRequires maintenance-level access. Where MTConnect is in use, confirm the agent is reachable as well as the machine.

Every entry above is published machine operation, documented in each builder's own manual. None of it describes how MachineWise reads a control — that is configured by our engineering team and is a separate matter entirely.

Static address or DHCP reservation?

Either is fine. What is not fine is an ordinary DHCP lease, because it will eventually change and monitoring will lose the machine without any obvious error — data simply stops, usually on a weekend.

A static address set on the control is simplest where you control the range and keep a written list. A DHCP reservation pins an address to the machine's hardware address at the server, which suits plants with an IT function that would rather manage addresses centrally. Both give the same outcome: an address that does not move.

For gateway-connected machines the same rule applies to the gateway rather than the machine, and the uplink may be Ethernet, Wi-Fi or 4G depending on where the machine sits.

Verification, in the right order

STEP 1Ping from the same subnetA laptop on the same segment. If this fails, the problem is the control, the cable or the port.
STEP 2Ping from the monitoring serverThis is the test that matters. Reachable from a laptop but not the server means a routing or segmentation issue, not a machine issue.
STEP 3Check for duplicatesDisconnect the machine and ping its address again. Anything that answers is a conflict, and this is the fault that wastes the most commissioning time.
STEP 4Record itMachine number, address, mask, gateway, switch port, date. Kept with the machine records, not in an email.

Step 3 is the one nearly everyone skips, and duplicate addressing is the single most common cause of a monitoring connection that works intermittently. On floors with several machines of the same make commissioned years apart, defaults collide more often than anyone expects.

The five faults that account for most delays

FAULT 01

Duplicate address

Two machines commissioned years apart sharing a default. Symptoms are intermittent, which makes it hard to diagnose and easy to blame on software.

FAULT 02

Subnet mask mismatch

The machine looks correctly configured and is unreachable from the server. Check the mask before checking anything else.

FAULT 03

Wrong interface cabled

Particularly on controls with separate system, service and plant-network ports. The cable is in a port that was never meant to reach your network.

FAULT 04

DHCP lease expiry

Worked for weeks, then stopped. Almost always an unreserved lease that moved.

FAULT 05

Segmentation blocking the server

Reachable from the floor, not from the server. A routing question for IT, not a machine problem.

A sheet worth keeping

FieldWhy it is on the sheet
Machine number and makeSo the row can be matched to the asset register
IP addressThe thing you will look up most often
Subnet mask and gatewayBecause a mismatch here is the second most common fault
Switch and portSo a physical trace takes a minute rather than an hour
Static or reservationSo the next person knows whether to look at the control or the DHCP server
Date and who set itSo a disputed change can be traced to a decision

This sheet belongs with the machine records alongside the PLC backup and the mapping document. It costs ten minutes per machine and it is the difference between a connection problem taking five minutes and taking an afternoon.

Questions

Straight answers.

How do I set the IP address on a FANUC control?
Through the SYSTEM key and the Ethernet or Embedded Ethernet screens reached via the soft keys, where address, subnet mask and gateway are entered. Confirm whether the embedded port or an optional Ethernet board is cabled, as they are configured separately, and expect to power-cycle the control.
Where are network settings on a Siemens SINUMERIK?
In the HMI setup or start-up area, under network or TCP/IP configuration. These controls separate a system-network port for internal drive traffic, a service port and a plant-network port — configure the plant-network interface, X130 on many variants.
Which Mitsubishi parameters hold the IP address?
On M700 and M800 series the address, subnet mask and gateway are commonly held in the #1926 to #1928 parameter group, reached through the maintenance or parameter screens. Verify against your machine's manual, and power-cycle afterwards.
How do I configure the network on a Haas?
On the Next Generation Control, Settings tab then the Network page: switch Wired DHCP off, then enter address, mask, gateway and DNS. On the Classic control the same values are in the 900-series numbered settings, usually needing a power cycle.
Should I use a static IP or DHCP?
Either a static address or a DHCP reservation tied to the machine. Never an ordinary DHCP lease — it will change and monitoring will lose the machine with no obvious error, usually on a weekend.
What is the most common connection fault?
Duplicate addressing, by a wide margin. Machines of the same make commissioned years apart often share a default. Test by disconnecting the machine and pinging its address — anything that answers is a conflict.